With increased demand for evaluation of oxidative resistance to chlorinated water, im体育APP offers extensive testing capacity to demonstrate the chlorine resistance of plastic piping materials and systems. We apply ASTM F2023 (PEX, 耐热聚乙烯), Astm f2263 (pe), and ASTM F3497-21 (PP) for testing and evaluation of the long-term chlorine performance.

 

Chlorine resistance testing is part of im体育APP's global 塑料管道 & 配件测试 program, provided to resin manufacturers, 管挤出机, certification bodies and utility companies worldwide, where independent, reliable and reproducible test data is required for product classification and life time evaluation.

 

Evaluation of oxidative resistance to hot chlorinated water 

Chlorine resistance tests are performed to evaluate the oxidative resistance of piping materials and systems to chlorinated water. While many pipe materials have proved to be resistant to degradation, the ageing process can accelerate under more aggressive conditions with significant impact on lifetime and durability. 例如, the common use of chlorine for disinfection purposes is increasing the importance of evaluating chlorine resistance of piping materials and systems.

Our accredited facility generates reliable and reproducible chlorine resistance data for an extensive range of pipe dimensions and assemblies with a capacity of 200 chlorine test stations, allowing our customers to use the test results for certification to “ANSI NSF”.

 

测试 to ASTM F2023, ASTM F2263 and ASTM F3497-21

For chlorine resistance tests im体育APP applies the standard methodology of ASTM F2023 (PEX, 耐热聚乙烯), Astm f2263 (pe), and ASTM F3497-21(PP) for testing and evaluation of the long term chlorine performance. These methods can also be used for other piping materials.

 

测试原理

The testing is conducted under accelerated conditions at elevated temperatures and pressures. The most common and accepted approach is to perform exposure under ”worst case” conditions.

 

Standard test conditions

  • Dimensions: up to OD 63 mm (2” US)
  • Capacity: >200 pipe samples
  • Temperatures: 40-120 °C
  • Chlorine concentration: 0.5 – 4.3 PPM (mg/dm3), others are available upon request
  • pH: 6.8 is set as standard (others on request)
  • 流量:54dm3/h (others are available upon request)

 

For more information about our chlorine resistance testing, or to request a quote, 立即im体育APP.

We're here to help. Engage with an expert today.

Our plastic pipes testing facility in Sweden is one of only a handful across the globe with a capacity of 5,000 test stations. We provide independent, reliable and reproducible test data for product classification and life time evaluation. Contact our team to discuss your test projects.